CFPQT - SEMI-GLOSS RED ENAMEL 595-21105, 25-F8-300 BASE
- MSDS: CFPQT
- Manufacturer: CROWN METRO AEROSPACE COATINGS INC
- Product Name: SEMI-GLOSS RED ENAMEL 595-21105, 25-F8-300 BASE
- National Stock Number: 8010-00N079924
Product Identification
Product ID:SEMI-GLOSS RED ENAMEL 595-21105, 25-F8-300 BASE
MSDS Date:02/01/1990
FSC:8010
NIIN:00N079924
MSDS Number: CFPQT
Responsible Party
US
Emergency Phone: 803-277-1870
Info Phone: 803-277-1870
Cage: CROME
Contractor
Telephone: 803-277-1870
Cage: 0S4B8
Ingredients
POLYESTER RESIN
Fraction By Weight: 15%
OSHA PEL N/K
ACGIH TLV: N/K
CADMIUM; (CADMIUM SULFO SELENIDE) (SARA 313) (CERCLA)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 10%
OSHA PEL 0.2 MG/M3 DUST
ACGIH TLV: 0.01 MG/M3 DUST
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: 15%
OSHA PEL 20 MPPCF
ACGIH TLV: 2 MG/M3 RDUST
10
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 5%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM;200 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 15%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM;300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE
CAS: 108-65-6
RTECS: AI8925000
Fraction By Weight: 10-15%
OSHA PEL N/K
ACGIH TLV: N/K
DECOMPOSITION PRODUCTS MAY CAUSE HLTH HAZ.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:CAN CAUSE IRRITATION TO SKIN, EYES AND
RESPIRATORY TRACT. SYMPTOMS MAY BE WATERING OF EYES, DRYNESS OF
THROAT, COUGHING, HEADACHE, TIGHTNESS IN CHEST OR BURNING
SENSATION. ALLERGIC REACTIONS MAY OCCUR IN SOME INDIVIDUALS.
HEADACHE, DIZZINESS OR NAUSEA MAY BE EXPERIENCED BY SOME AS A
RESULT OF EXPOSURE TO SOLVENTS.
Explanation of Carcinogenicity:CADMIUM:IARC MONOGRAPHS, SUPP, VOL 7, PG
139, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE
(SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PERSONS W/ASTHMATIC TYPE
CONDITIONS, CHRONIC BRONCHITIS OR OTHER CHRONIC RESPIRATORY
DISEASES OR RECURRENT SKIN ECZEMA OR SENSITIZATION SHOULD BE
EXCLUDED FROM WORKING W/THIS PRODUCT.
First Aid
First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. CONSULT MD.
SKIN:WASH AFFECTED AREA W/SOAP & WATER. REMOVE CONTAMINATED
CLOTHING. CONSULT MD. INHAL:REMOVE TO FRESH AIR. CONSULT MD.
INGEST:DRINK WATER TO D ILUTE. DO NOT INDUCE VOMITING. CONSULT MD.
Fire Fighting
Flash Point Method:TCC
Flash Point:23.0F,-5.0C
Lower Limits:1%
Extinguishing Media:USE NFPA CLASS B EXTINGUISHERS. FOAM, "ALCOHOL"
FOAM, CO*2, DRY CHEMICALS, WATER FOG.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:CLASS IB-FLAMM LIQ. KEEP CNTNRS TIGHTLY
CLSD. ISOLATE FROM HEAT, SPKS, ELEC EQUIP & OPEN FLAME. CLSD CNTNRS
MAY EXPLODE WHEN EXPOS TO EXTREME HEAT. (SUPP DATA)
Accidental Release
Spill Release Procedures:EVACUATE NON-ESSNTL PERSONNEL. REMOVE ALL
SOURCES OF IGNITION (SPARKS, FLAMES, HOT SURFACES). VENTILATE AREA.
EQUIP CLEAN UP CREW W/NIOSH APPROVED SCBA. DIKE SPILL. COVER
W/SAWDUST, VERMICULITE OR FUL LER'S EARTH. COLLECT MATERIAL IN OPEN
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE ABOVE 100F. STORE IN
LARGE QUANTITIES ONLY IN BUILDINGS DESIGNED TO COMPLY W/OSHA
1910.106. SHELF LIFE:ONE YEAR FROM DATE OF MANUFACTURE.
Other Precautions:KEEP CONTAINERS CLOSED & UPRIGHT TO PREVENT LEAKAGE.
DO NOT STORE OR USE NEAR HEAT, SPARKS OR FLAMES. AVOID PROLONGED OR
REPEATED CONTACT W/VAPOR OR SPRAY MIST DURING APPLICATION OR
CURING.
Exposure Controls
Respiratory Protection:IN OUTDOOR OR OPEN AREAS USE NIOSH APPROVED
MECHANICAL FILTER RESPIRATOR. IN RESTRICTED VENT AREAS, USE NIOSH
APPROVED CHEM/MECH FILTERS TO REMOVE VAPS & PARTICULATES. IN
CONFINED AREAS, USE NIOSH APP ROVED AIR LINE TYPE RESPS OR HOODS.
Ventilation:MUST BE SUFFICIENT IN VOLUME & PATTERN TO KEEP CONTAMINANT
CONCENTRATION BELOW TLV (NIOSH) OR PEL (OSHA).
Protective Gloves:BUTYL RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . WEAR CHEM RESIST BOOTS. PROT CREAMS WHERE SKIN CONT IS
LIKELY.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING BATHROOM.
REMOVE & WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
FIRE FIGHT PROC:PREVENT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOS TO EXTREME HEAT. EXPLAN OF CARCIN:CARCIN. HUMAN:LUNG,
PROSTATE, RENAL SYS EFTS. OSHA REGULATED:29 CFR 1910.1027. EYE
PROT:& FUL L LGTH FSHLD . EXPLO HAZ:APPLICATION TO HOT SURFS REQS
SPECIAL PRECS. DURING EMER CNDTNS, OVEREXP TO (ING 7)
Chemical Properties
Boiling Pt:B.P. Text:>175F,>79C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.07
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:72
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:TEMPERATURE ABOVE MAXIMUM STORAGE
TEMPERATURE. AVOID EXPOSURE TO HEAT, SPARKS OR OPEN FLAMES.
Hazardous Decomposition Products:BY FIRE - CO, CO*2, NITROGEN OXIDES &
TRACES OF HCN & HDI.
Disposal
Waste Disposal Methods:CONFORM TO FEDERAL, STATE & LOCAL REGULATIONS.
EMPTY CONTAINERS MUST BE HANDLED CAREFULLY DUE TO PRODUCT RESIDUE &
FLAMMABLE SOLVENT VAPOR.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.